Hi all,
I like the way Nophead\Marlin has the HOME_POS and other settings tuned to the Mendel 90 design.
But, there is a new feature in the main release of Marlin that I also very much like and want to try out. It's the "Automatic operation of extruder/cold-end cooling fans based on nozzle temperature" feature. I think feature will work with my Azteeg X3 board which I have on my Mendel 90.
I currently have Chris' tuned Marlin (https://github.com/nophead/Marlin) installed on the Azteeg and it works, but I'd like the new feature from the new Marlin version.
Any suggestions on what I can do to get the best of both worlds?
I've a basic understanding of Marlin settings, but can't figure what I might need to move from one version to the other to get the benefit of both. The new "Auto-operation of cooling fan" feature is set in a section of Configuration_Adv.h tab. With my limited knowledge of this I've no way of knowing if there are other depend entries in other tabs that I'd also need to copy, if I try copy/pasting from one to the other.
Would it be easier for me to move Chris' changes into a downloaded current Marlin and get that going? (I'm fine with setting EndStops, Directions, E_Steps and that kind of stuff).
Any suggestions welcome.
NumberSix
I like the way Nophead\Marlin has the HOME_POS and other settings tuned to the Mendel 90 design.
But, there is a new feature in the main release of Marlin that I also very much like and want to try out. It's the "Automatic operation of extruder/cold-end cooling fans based on nozzle temperature" feature. I think feature will work with my Azteeg X3 board which I have on my Mendel 90.
I currently have Chris' tuned Marlin (https://github.com/nophead/Marlin) installed on the Azteeg and it works, but I'd like the new feature from the new Marlin version.
Any suggestions on what I can do to get the best of both worlds?
I've a basic understanding of Marlin settings, but can't figure what I might need to move from one version to the other to get the benefit of both. The new "Auto-operation of cooling fan" feature is set in a section of Configuration_Adv.h tab. With my limited knowledge of this I've no way of knowing if there are other depend entries in other tabs that I'd also need to copy, if I try copy/pasting from one to the other.
Would it be easier for me to move Chris' changes into a downloaded current Marlin and get that going? (I'm fine with setting EndStops, Directions, E_Steps and that kind of stuff).
Any suggestions welcome.
NumberSix